SECTION 213 - L

LINTEL is a structural member placed over an opening or a recess in a wall and supporting construction above.

LIQUID is any material which has a fluidity greater than that of 300 penetration asphalt when tested in accordance with the Uniform Fire Code Standards. When not otherwise identified, the term ``liquid'' is both flammable and combustible liquids.

LIQUID STORAGE ROOM is a room classified as a Group H, Division 3 Occupancy used only for the storage of flammable or combustible liquids in a closed condition. The quantities of flammable or combustible liquids in storage shall not exceed the limits set forth in the Fire Code.

LIQUID STORAGE WAREHOUSE is a Group H, Division 3 Occupancy used only for the storage of flammable or combustible liquids in an unopened condition. The quantities of flammable or combustible liquids stored are not limited.

LISTED and LISTING are terms referring to equipment or materials included in a list published by an approved testing laboratory, inspection agency or other organization concerned with product evaluation that maintains periodic inspection of current productions of listed equipment or materials. The published list shall state that the material or equipment complies with approved nationally recognized codes, standards or tests and has been tested or evaluated and found suitable for use in a specified manner.

LOADS. See Chapter 16.

LODGING HOUSE is any building or portion thereof containing not more than five guest rooms where rent is paid in money, goods, labor or otherwise.

LOW-PRESSURE HOT-WATER-HEATING BOILER is a boiler furnishing hot water at pressures not exceeding 160 psi (1102.4 kPa) and at temperatures not exceeding 250°F. (121°C.).

LOW-PRESSURE STEAM-HEATING BOILER is a boiler furnishing steam at pressures not exceeding 15 psi (103.4 kPa).