SECTION 220 - S

SELF-LUMINOUS means powered continuously by a self-contained power source other than a battery or batteries, such as radioactive tritium gas. A self-luminous sign is independent of external power supplies or other energy for its operation.

SENSITIZER is a chemical that causes a substantial proportion of exposed people or animals to develop an allergic reaction in normal tissue after repeated exposure to the chemical.

SERVICE CORRIDOR is a fully enclosed passage used for transporting hazardous production materials and for purposes other than required exiting.

SHAFT is an interior space, enclosed by walls or construction, extending through one or more stories or basements which connects openings in successive floors, or floors and roof, to accommodate elevators, dumbwaiters, mechanical equipment or similar devices or to transmit light or ventilation air.

SHAFT ENCLOSURE is the walls or construction forming the boundaries of a shaft.

SHALL, as used in this code, is mandatory.

SMOKE DETECTOR is an approved, listed device that senses visible or invisible particles of combustion.

STAGE. See Chapter 4.

STORY is that portion of a building included between the upper surface of any floor and the upper surface of the floor next above, except that the topmost story shall be that portion of a building included between the upper surface of the topmost floor and the ceiling or roof above. If the finished floor level directly above a usable or unused under-floor space is more than 6 feet (1829 mm) above grade as defined herein for more than 50 percent of the total perimeter or is more than 12 feet (3658 mm) above grade as defined herein at any point, such usable or unused under-floor space shall be considered as a story.

STORY, FIRST, is the lowest story in a building which qualifies as a story, as defined herein, except that a floor level in a building having only one floor level shall be classified as a first story, provided such floor level is not more than 4 feet (1219 mm) below grade, as defined herein, for more than 50 percent of the total perimeter, or not more than 8 feet (2438 mm) below grade, as defined herein, at any point.

STREET is any thoroughfare or public way not less than 16 feet (4877 mm) in width which has been dedicated or deeded to the public for public use.

STRUCTURAL OBSERVATION means the visual observation of the structural system, for general conformance to the approved plans and specifications, at significant construction stages and at completion of the structural system. Structural observation does not include or waive the responsibility for the inspections required by Section 108, 1701 or other sections of this code.

STRUCTURE is that which is built or constructed, an edifice or building of any kind, or any piece of work artificially built up or composed of parts joined together in some definite manner.

SURGICAL AREA is the preoperating, operating, recovery and similar rooms within an outpatient health-care center.