SECTION 316 - CONSTRUCTION, REQUIREMENT EXCEPTIONS

316.1 General. Except as provided in this appendix chapter, buildings shall be constructed in accordance with the provisions of this code.

316.2 Exceptions to Table 6-A. Regardless of the provisions of Table 6-A, nonbearing cell walls within cell complexes may be of nonfire-rated, noncombustible construction, provided the cell complex is separated from all other areas of the building, including corridors which connect to the cell complex by construction and opening protection as required for exit corridors.

The open space in front of a cell tier not exceeding two tiers in height in detention or correctional facilities shall not be considered a vertical shaft whether extending from the floor to ceiling above or from floor to underside of roof.