SECTION 317 - COMPARTMENTATION

Every story having an occupant load of more than 50 inmates in a detention or correctional facility shall be divided into not less than two approximately equal compartments by a smoke-stop partition, constructed pursuant to the provisions of Section 308.2.

EXCEPTIONS: 1. Protection may be accomplished with horizontal exits. (See Section 1008.)

2. In restraint areas there are no restrictions on the total number area of glazed openings in a smoke barrier, provided vision panels are of glazing material as specified in Section 713.9.