SECTION 325 - FENCED ENCLOSURES

Exterior fenced enclosures into which an exit from a building or buildings terminate shall be provided with a safe dispersal area located not less than 50 feet (15 420 mm) from any building. Dispersal areas shall be based on an area of not less than 3 square feet (0.2787 ) per occupant. A gate shall be provided from the safe dispersal area to allow for necessary relocation of occupants.

Exterior fenced enclosures used for exit termination and which do not provide a safe dispersal area shall have not less than two exits.

Fenced enclosures located on roofs of buildings one or more stories in height shall be provided with not less than two exits regardless of occupant load.

Fenced enclosures used for recreational or activity purposes only shall be provided with exits in accordance with Section 1003.