Except where Table 6-A requires greater protection, exterior walls of agricultural buildings shall not be less than one-hour fire-resistive construction when less than 20 feet (6096 mm) from property line.
Openings in exterior walls of agricultural buildings
which are less than 20 feet (6096 mm) from property lines shall
be protected by fire assemblies having a fire-protection rating
of not less than three-fourths hour.