SECTION 330 - EXIT FACILITIES

Exit facilities shall be as specified in Chapter 10.

EXCEPTIONS: 1. The maximum distance of travel from any point in the building to an exterior exit door, horizontal exit, exit passageway or an enclosed stairway shall not exceed 300 feet (91 440 mm).

2. One exit is required for each 15,000 square feet (1394 ) of floor area and fraction thereof.

3. Exit openings shall not be less than 2 feet 6 inches by 6 feet 8 inches (763 mm by 2032 mm).