SECTION 603 - TYPE II BUILDINGS

603.1 Definition. The structural elements in Type II-F.R. buildings shall be of steel, iron, concrete or masonry.

The structural elements of Type II One-hour or II-N buildings shall be of noncombustible materials.

Floor construction of Type II One-hour and Type II-N buildings shall be of noncombustible material, provided, however, that a wood surface or finish may be applied over such noncombustible material.

Walls and permanent partitions of Type II-F.R. buildings shall be of noncombustible fire-resistive construction, except that permanent nonbearing partitions of one-hour or two-hour fire-resistive construction, which are not part of a shaft enclosure, may have fire-retardant-treated wood (see Section 207) within the assembly.

Type II One-hour buildings shall be of noncombustible construction and one-hour fire resistive throughout except that permanent nonbearing partitions may use fire-retardant-treated wood (see Section 207) within the assembly, provided fire-resistive requirements are maintained.

Walls and permanent partitions of Type II-N buildings shall be of noncombustible materials.

Materials of construction and fire-resistive requirements shall be as specified in Section 601.

For requirements due to occupancy, see Chapter 3.

603.2 Structural Framework. Structural framework shall be as specified in Chapter 22 for iron and steel, Chapter 19 for concrete and Chapter 21 for masonry.

603.3 Exterior Walls and Openings.

603.3.1 Exterior walls. Exterior walls and all structural members shall comply with the requirements specified in Section 503 and Table 5-A and the fire-resistive provisions set forth in Table 6-A.

603.3.2 Openings in walls. All openings in exterior walls of Type II-F.R. buildings shall conform to the requirements of Section 503.2 and Table 5-A.

603.4 Stairway Construction. Stairways of Type II-F.R. buildings shall be constructed of reinforced concrete, iron or steel with treads and risers of concrete, iron or steel. Brick, marble, tile or other hard noncombustible materials may be used for the finish of such treads and risers. Stairways of Type II One-hour and Type II-N buildings shall be of noncombustible construction.

Stairways shall comply with the requirements of Chapter 10.

603.5 Roofs. Roofs shall be of noncombustible construction, except that in Type II-F.R. and Type II One-hour buildings, roofs may be as specified in Section 602.5.

Roof coverings shall be as specified in Chapter 15.

Go to Table of Contents