SECTION 804 - MAXIMUM ALLOWABLE FLAME SPREAD

804.1 General. The maximum flame-spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table 8-B.

EXCEPTIONS: 1. Except in Group I Occupancies and in enclosed vertical exitways, Class III may be used in other exitways and rooms as wainscoting extending not more than 48 inches (1219 mm) above the floor and for tack and bulletin boards covering not more than 5 percent of the gross wall area of the room.

2. When a sprinkler system complying with U.B.C. Standard 9-1 or 9-3 is provided, the flame-spread classification rating may be reduced one classification, but in no case shall materials having a classification greater than Class III be used.

3. The exposed faces of Type IV-H.T., structural members and Type IV-H.T., decking and planking, where otherwise permissible under this code, are excluded from flame-spread requirements.

804.2 Carpeting on Ceilings. When used as interior ceiling finish, carpeting and similar materials having a napped, tufted, looped or similar surface shall have a Class I flame spread.