SECTION 1011 - EXIT PASSAGEWAYS

1011.1 Construction and Openings. The walls of exit passageways shall be without openings other than required exits from normally occupied spaces and shall have walls, floors and ceilings of the same period of fire resistance as required for the walls, floors and ceilings of the building served with a minimum of one-hour fire-resistive construction. Exit openings through the enclosing walls of exit passageways shall be protected by fire assemblies having a three-fourths-hour fire-protection rating.

1011.2 Detailed Requirements. Except for construction and opening protection as specified in Section 1011.1 above, exit passageways shall comply with the requirements for corridors as specified in Section 1005.