SECTION 1015 - SEAT SPACING

When seating rows have 14 or less seats, the minimum clear width between rows shall not be less than 12 inches (305 mm) measured as the clear horizontal distance from the back of the row ahead and the nearest projection of the row behind. Where seats are automatic or self-rising, measurement may be made with the seats in the raised position. Where seats are not automatic or self-rising, the minimum clear width shall be measured with the seat in the down position.

The clear width shall be increased as follows:

1. For rows of seating served by aisles or doorways at both ends, there shall be no more than 100 seats per row and the minimum clear width of 12 inches (305 mm) between rows shall be increased by 0.3 inch (7.62 mm) for every additional seat beyond 14, but the minimum clear width need not exceed 22 inches (559 mm). If the aisles are dead ended, see Section 1014.4 for further limitations.

2. For rows of seating served by an aisle or doorway at one end only, the minimum clear width of 12 inches (305 mm) between rows shall be increased by 0.6 inch (15 mm) for every additional seat beyond seven, but the minimum clear width need not exceed 22 inches (559 mm). In addition, the distance to the point where the occupant has a choice of two directions of travel to an exit shall not exceed 30 feet (9144 mm) from the point where the occupant is seated.

Go to Table of Contents
Go to previous section: 1014
Go to next section: 1016


Commercial Asbuilts: BOMA Asbuilt | Definitions | Projects | Project Types | FAQ | Useful links
Residential Asbuilts: Projects | Asbuilt Services | FAQ
Contact | Copyright | Privacy Policy | Site Map | News