SECTION 1510 - ROOF INSULATION

Roof insulation shall be of a rigid type suitable as a base for application of a roof covering. Foam plastic roof insulation shall conform to the requirements of Section 2602. The use of insulation in fire-resistive construction shall comply with Section 710.1.

The roof insulation, deck material and roof covering shall meet the fire-retardancy requirements of Section 1504 and Table 15-A.

Insulation for built-up roofs shall be applied in accordance with Table 15-E. Insulation for modified bitumen, thermoplastic and thermoset membrane roofs shall be applied in accordance with the roofing manufacturer's recommendations. For other roofing materials such as shingles or tile, the insulation shall be covered with a suitable nailing base secured to the structure.