SECTION 1512 - TOWERS AND SPIRES

Towers or spires when enclosed shall have exterior walls as required for the building to which they are attached. Towers not enclosed and which extend more than 75 feet (22 860 mm) above grade shall have their framework constructed of iron, steel or reinforced concrete. No tower or spire shall occupy more than one fourth of the street frontage of any building to which it is attached and in no case shall the base area exceed 1,600 square feet (149 ) unless it conforms entirely to the type of construction requirements of the building to which it is attached and is limited in height as a main part of the building. If the area of the tower or spire exceeds 100 square feet (9.29 ) at any horizontal cross section, its supporting frame shall extend directly to the ground. The roof covering of spires shall be as required for the main roof of the rest of the structure.

Skeleton towers used as radio masts and placed on the roof of any building shall be constructed entirely of noncombustible materials when more than 25 feet (7620 mm) in height and shall be directly supported on a noncombustible framework to the ground. They shall be designed to withstand a wind load from any direction as specified in Chapter 16, Part II, in addition to any other loads.

Go to Table of Contents
Go to previous section: 1511
Go to next section: 1513


Commercial Asbuilts: BOMA Asbuilt | Definitions | Projects | Project Types | FAQ | Useful links
Residential Asbuilts: Projects | Asbuilt Services | FAQ
Contact | Copyright | Privacy Policy | Site Map | News