SECTION 1515 - INSPECTIONS

New roof coverings shall not be applied without first obtaining an inspection by the building official and written approval from the building official. A final inspection and approval shall be obtained from the building official when the reroofing is complete. The preroofing inspection shall pay particular attention to evidence of accumulation of water. Where extensive ponding of water is apparent, an analysis of the roof structure for compliance with Section 1506 shall be made and corrective measures, such as relocation of roof drains or scuppers, resloping of the roof or structural changes, shall be made.

An inspection report covering the above-listed topics prepared by a special inspector may be accepted in lieu of the preinspection by the building official.