SECTION 1823 - WALL DAMPPROOFING

1823.1 General. Dampproofing materials shall be installed on the exterior surface of walls, and shall extend from a point 6 inches (152 mm) above grade, down to the top of the spread portion of the footing.

1823.2 Surface Preparation. Prior to application of dampproofing materials on concrete walls, fins or sharp projections that may pierce the membrane shall be removed and all holes and recesses resulting from the removal of form ties shall be sealed with a dry-pack mortar, bituminous material, or other approved methods or materials.

1823.3 Dampproofing Materials. Wall dampproofing shall consist of a bituminous material, acrylic modified cement base coating, any of the materials permitted for waterproofing in Section 1827.4, or other approved methods or materials. When such materials are not approved for direct application to unit masonry, the wall shall be parged on the exterior surface below grade with not less than 3/8 inch (10 mm) of portland cement mortar.