SECTION 2905 - GENERAL

Each building shall be provided with sanitary facilities, including provisions for accessibility in accordance with Chapter 11. Plumbing fixtures shall be provided for the type of building occupancy with the minimum numbers as shown in Table A-29-A. The number of fixtures are the minimum required as shown in Table A-29-A and are assumed to be based on 50 percent male and 50 percent female. The occupant load factors shall be as shown in Table A-29-A.

EXCEPTION: Where circumstances dictate that a different ratio is needed, the adjustment shall be approved by the building official.