SECTION 3004 - HOISTWAY VENTING

Shafts (hoistways) housing elevators extending through more than two floor levels shall be vented to the outside. The area of the vent shall not be less than 3 1/2 percent of the area of the elevator shaft, provided a minimum of 3 square feet (0.279 ) per elevator is provided. Vents shall be capable of manual operation only.

**********

The venting of each individual hoistway shall be independent from any other hoistway venting, and the interconnection of separate hoistways for the purpose of venting is prohibited.