SECTION 3114 - SECTION PROVISIONS

A system capable of supporting the membrane in the event of deflation shall be provided in all air-supported and air-inflated structures having an occupant load of more than 50 or when covering a swimming pool regardless of occupant load. Such system shall maintain the membrane at least7 feet (2134 mm) above the floor, seating area or surface of the water.

EXCEPTION: Membrane structures used as a roof for Type I or Type II fire-resistant construction must be maintained not less than 25 feet (7620 mm) above floor or seating areas.