SECTION 3205 - MARQUEES

3205.1 General. For the purpose of this section a marquee shall include any object or decoration attached to or a part of said marquee.

3205.2 Projection and Clearance. The horizontal clearance between a marquee and the curb line shall not be less than 2 feet (610 mm).

A marquee projecting more than two thirds of the distance from the property line to the curb line shall not be less than 12 feet (3658 mm) above the ground or pavement below.

A marquee projecting less than two thirds of the distance from the property line to the curb line shall not be less than 8 feet (2438 mm) above the ground or pavement below.

3205.3 Length. A marquee projecting more than two thirds of the distance from the property line to the curb line shall not exceed 25 feet (7620 mm) in length along the direction of the street.

3205.4 Thickness. The maximum height or thickness of a marquee measured vertically from its lowest to its highest point shall not exceed 3 feet (914 mm) when the marquee projects more than two thirds of the distance from the property line to the curb line and shall not exceed 9 feet (2743 mm) when the marquee is less than two thirds of the distance from the property line to the curb line.

3205.5 Construction. A marquee shall be supported entirely by the building and constructed of noncombustible material or, when supported by a building of Type V construction, may be of one-hour fire-resistive construction.

3205.6 Roof Construction. The roof or any part thereof may be a skylight, provided glass skylights are of laminated or wired glass complying with Section 2409. Plastic skylights shall comply with Section 2603.7.

Every roof and skylight of a marquee shall be sloped to downspouts which shall conduct any drainage from the marquee under the sidewalk to the curb.

3205.7 Location Prohibited. Every marquee shall be so located as not to interfere with the operation of any exterior standpipe or to obstruct the clear passage of stairways or exits from the building or the installation or maintenance of electroliers.